IRDye 800CW Donkey anti-Guinea Pig IgG Secondary Antibody

IRDye® 800CW Donkey anti-Guinea Pig IgG Secondary Antibody

IRDye 800CW Donkey anti-Guinea Pig IgG Secondary Antibody

Highly cross-adsorbed donkey anti-guinea pig IgG (H+L) antibody conjugated to IRDye 800CW.

Immunogen

Guinea Pig IgG, whole molecule

Purity and Specificity

Isolation of specific antibodies was accomplished by affinity chromatography using antigens immobilized on agarose beads. Based on immunoelectrophoresis and/or ELISA, this antibody reacts with whole molecule guinea pig IgG as well as the light chains common to other guinea pig immunoglobulins. No reactivity was detected against non-immunoglobulin serum proteins. This antibody has been tested by ELISA and/or solid-phase adsorbed to ensure minimal cross-reactivity with bovine, chicken, goat, Syrian hamster, horse, human, mouse, rabbit, rat, and sheep serum proteins. The conjugate has been specifically tested and qualified for Western blot and In-Cell Western Assay applications.

Applications

Highly recommended for:

  • Western Blot
  • In-Cell Western Assay
  • On-Cell Western Assay
  • Protein Array
  • Immunohistochemistry
  • Small Animal Imaging
  • Microscopy
  • 2D Gel Detection
  • Tissue Section Imaging
  • Virus Titration Assay

Formulation

IRDye 800CW Secondary Antibodies are supplied as purified immunoglobulin conjugates, lyophilized in phosphate-buffered saline, pH 7.4. Protect from light. Store at 4 °C prior to reconstitution.

Each vial contains 10 mg/mL BSA (free of IgG and protease) as a stabilizer and 0.01% sodium azide as a preservative, after reconstitution. Concentration is 1.0 mg/mL when reconstituted as directed. Refer to the pack insert for details on reconstitution.

Recommended Dilutions

Application Recommended Suggested Range
Odyssey Western blot detection 1:20,000 1:5,000 - 1:25,000
In-Cell Western Assay detection 1:800 1:200 - 1:1,200
Other User optimized

Optimum dilutions will vary and should be determined empirically.

RRID

  • P/N 925-32411: RRID AB_2814905
  • P/N 926-32411: RRID AB_1850024

Example Data

IRDye® 800CW Donkey anti-Guinea Pig IgG Secondary Antibody data
Detection of guinea pig IgG with IRDye 800CW Donkey anti-Guinea Pig. Serial dilutions of Guinea Pig IgG were spiked into C32 lysate (Santa Cruz P/N sc-2205). Samples were resolved on a 10% Bis-Tris gel and transferred to Odyssey® Nitrocellulose membrane (P/N 926-31092). The membrane was blocked with Odyssey Blocking Buffer (P/N 927-40000) followed by detection with IRDye 800CW Donkey anti-Guinea Pig (P/N 926-32411).
+ Read More

Selected P/N: 926-32411,925-32411